Structural fill solutions are evolving—and R-Shield® Geofoam is leading the way with lightweight, high-performance alternatives to traditional materials. One of the most important aspects of using geofoam in structural and civil engineering applications is selecting the correct grade for the expected load.
R-Shield's Technical Team has provided three detailed calculation examples to help engineers understand how to evaluate vertical stresses in geofoam and verify that the selected product is suitable for real-world conditions. Let’s explore what each example illustrates.
This first scenario models a straightforward case: a single 12.5 kip point load applied over a layered pavement system (pavement, base, and 6 feet of geofoam). The goal is to verify that the selected EPS 22 Geofoam, with a compressive resistance of 7.3 psi at 1% strain, can withstand the combined dead and live loads.
Key Takeaways:
Result: EPS 22 is suitable for this single-load application.
This second scenario increases complexity by analyzing two adjacent 12.5 kip loads (simulating dual tires), introducing load overlap as a critical factor. The model incorporates both transverse and longitudinal load distributions, reflecting real-world wheel loading on roadways or parking decks.
Key Takeaways:
Result: EPS 22 still passes, proving its performance under more dynamic and complex loading conditions.
Key Takeaways:
Result: EPS 22 continues to perform, even in a high-demand, multi-load scenario.
These examples are more than just theoretical—they reflect common project scenarios like:
They illustrate how to apply NCHRP-based simplified stress distribution models to calculate load suitability for geofoam. While simplified, they provide a solid starting point and reinforce the importance of:
Whether you're designing for transportation, infrastructure, or commercial construction, R-Shield Geofoam offers a lightweight yet strong alternative to traditional fill materials. These load calculation examples highlight not only the performance of EPS 22 Geofoam, but also the engineering rigor behind proper material selection.
Need assistance selecting the right grade? R-Shield is here to help your team navigate design and specification with confidence. Contact us today!